  • Question 16 of 18

    The following circuit has a problem. When the switch is closed, the lamp does not turn on:



    Identify which of these hypothetical faults could account for this problem, and which could not account for the problem. In other words, which of these faults are possible, and which are not possible, given the symptoms exhibited by the circuit? Consider each of these hypothetical faults one at a time (no multiple, simultaneous faults):

    • Light bulb filament failed open
    • Switch failed shorted
    • Switch failed open
    Reveal answer
  • Question 17 of 18

    The following circuit has a problem. Switch #1 is able to control lamp #1, but lamp #2 never comes on no matter what is done with switch #2:



    Identify which of these hypothetical faults could account for this problem, and which could not account for the problem. In other words, which of these faults are possible, and which are not possible, given the symptoms exhibited by the circuit? Consider each of these hypothetical faults one at a time (no multiple, simultaneous faults):

    • Battery is dead
    • Switch #2 failed open
    • Switch #2 failed shorted
    • Switch #1 failed open
    • Switch #1 failed shorted
    • Open wire between test points 1 and 2 (between TP1 and TP2)
    • Open wire between test points 5 and 6 (between TP5 and TP6)
    Reveal answer
  • Question 18 of 18

    The following circuit has a problem. Switch #2 is able to control lamp #2, but lamp #1 never comes on no matter what is done with switch #1:



    Identify which of these hypothetical faults could account for this problem, and which could not account for the problem. In other words, which of these faults are possible, and which are not possible, given the symptoms exhibited by the circuit? Consider each of these hypothetical faults one at a time (no multiple, simultaneous faults):

    • Battery is dead
    • Lamp #1 filament failed open
    • Lamp #2 filament failed open
    • Switch #2 failed open
    • Switch #2 failed shorted
    • Switch #1 failed open
    • Switch #1 failed shorted
    • Open wire between test points 1 and 2 (between TP1 and TP2)
    • Open wire between test points 4 and 5 (between TP4 and TP5)
    • Open wire between test points 5 and 6 (between TP5 and TP6)
    Reveal answer